dc.description.abstractSubsidence is a common complication, especially in multisegment corpectomies. In addition to the characteristics of the cage, fixation method is also an effective means of preventing subsidence. We compared three different fixation methods used after the cage placement: Anterior fixation (AF), posterior fixation (PF), and circumferential fixation (CF). Low-density (LDB) and high-density (HDB) polyurethane blocks were used to mimic osteoporotic and normal bone, respectively. Five models within the groups loaded flexion-extension testing, and maximum compressive loads (MCL), bending moment and stiffness were determined in static tests. Subsequently, the specimens were subjected to dynamic fatigue tests then the amount of subsidence was calculated. The MCL and stiffness differences between AF, PF, and CF in the LDB were statistically significant, decreasing CF, PF, AF, respectively. In the HDB group, the difference in MCL between AF, PF, and CF was significant, decreasing from CF to PF to AF, respectively. The differences between the stiffness of these models were statistically significant, from high to low CF, PF, AF. The subsidence of AF, PF and CF in the LDB were 2.3 +/- 1.59 mm, 7.5 +/- 1.58 mm, and 0.65 +/- 0.10 mm, respectively. In this group, CF is more successful in preventing subsidence than AF and PF. Subsidence of less than 1 mm was observed in all models in the HDB. This study suggests that AF is as effective as other methods in preventing subsidence following two-level corpectomy in patients with high bone quality. In those with low bone quality, CF could provide more stable fixation and may be more reliable in preventing subsidence and potential instrumentation failure.en_US
dc.description.sponsorshipGazi niversitesi [TTU2021-7234]; Scientific Research Projects Department of Gazi Universityen_US
dc.description.sponsorshipThe author would like to acknowledge the Scientific Research Projects Department of Gazi University, Project # TTU2021-7234 and Osimplant Ltd. Sti. (Ankara, Turkey).en_US
dc.language.isoenen_US
dc.publisherSage Publications Ltden_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCervical Corpectomyen_US
dc.subjectCircumferential Fixationen_US
dc.subjectOsteoporotic Vertebraen_US
dc.subjectPolyurethane Blocksen_US
dc.subjectSubsidenceen_US
dc.titleEvaluating Fixation Techniques to Prevent Subsidence in Cervical Corpectomy Models Using Low and High-Density Polyurethane Blocksen_US
dc.typeArticleen_US
dc.departmentTOBB University of Economics and Technologyen_US
dc.identifier.wosWOS:001537274000001-
dc.identifier.doi10.1177/09544119251355721-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ2-
dc.identifier.wosqualityQ4-
dc.description.woscitationindexScience Citation Index Expanded-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.openairetypeArticle-
crisitem.author.dept02.7. Department of Mechanical Engineering-
Appears in Collections:WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.