Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/1529
Title: | Pullout Performance Comparison of Pedicle Screws Based on Cement Application and Design Parameters | Authors: | Tolunay, Tolga Başgül, Cemile Demir, Teyfik Yaman, Mesut E. Arslan, Arslan Kağan |
Keywords: | Pedicle screw pullout strength dual lead dual cored pedicle screw cannulated screw cement augmentation |
Publisher: | Sage Publications Ltd | Source: | Tolunay, T., Başgül, C., Demir, T., Yaman, M. E., & Arslan, A. K. (2015). Pullout performance comparison of pedicle screws based on cement application and design parameters. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 229(11), 786-793. | Abstract: | Pedicle screws are the main fixation devices for certain surgeries. Pedicle screw loosening is a common problem especially for osteoporotic incidents. Cannulated screws with cement augmentation are widely used for that kind of cases. Dual lead dual cored pedicle screw has already given promising pullout values without augmentation. This study concentrates on the usage of dual lead dual core with cement augmentation as an alternative to cannulated and standard pedicle screws with cement augmentation. Five groups (dual lead dual core, normal pedicle screw and cannulated pedicle screw with augmentation, normal pedicle screw, dual lead dual cored pedicle screw) were designed for this study. Healthy bovine vertebrae and synthetic polyurethane foams (grade 20) were used as embedding test medium. Test samples were prepared in accordance with surgical guidelines and ASTM F543 standard testing protocols. Pullout tests were conducted with Instron 3300 testing frame. Load versus displacement values were recorded and maximum pullout loads were stated. The dual lead dual cored pedicle screw with poly-methyl methacrylate augmentation exhibited the highest pullout values, while dual lead dual cored pedicle screw demonstrated similar pullout strength as cannulated pedicle screw and normal pedicle screw with poly-methyl methacrylate augmentation. The dual lead dual cored pedicle screw with poly-methyl methacrylate augmentation can be used for osteoporotic and/or severe osteoporotic patients according to its promising results on animal cadaver and synthetic foams. | URI: | https://www.ncbi.nlm.nih.gov/pubmed/26503840 https://hdl.handle.net/20.500.11851/1529 |
ISSN: | 0954-4119 |
Appears in Collections: | Makine Mühendisliği Bölümü / Department of Mechanical Engineering PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
11
checked on Dec 21, 2024
WEB OF SCIENCETM
Citations
13
checked on Aug 31, 2024
Page view(s)
68
checked on Dec 23, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.