dc.identifier.citation | Özkaya, E., Aradag, S., & Kakac, S. (2014, July). CFD Aided Design of Heat Transfer Plates for Gasketed Plate Heat Exchangers. In ASME 2014 12th Biennial Conference on Engineering Systems Design and Analysis (pp. V003T12A004-V003T12A004). American Society of Mechanical Engineers. | en_US |
dc.identifier.isbn | 978-0-7918-4585-1 | |
dc.identifier.uri | http://proceedings.asmedigitalcollection.asme.org/proceeding.aspx?articleid=1920129 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.11851/1543 | - |
dc.description.abstract | In this study, three-dimensional computational fluid dynamics (CFD) analyses are performed to assess the thermal-hydraulic characteristics of a commercial Gasketed Plate Heat Exchangers (GPHEx) with 30 degrees of chevron angle (Plate 1). The results of CFD analyses are compared with a computer. program (ETU HEX) previously developed based on experimental results. Heat transfer plate is scanned using photogrammetric scan method to model GPHEx. CFD model is created as two separate flow zones, one for each of hot and cold domains with a virtual plate. Mass flow inlet and pressure outlet boundary conditions are applied. The working fluid is water. Temperature and pressure distributions are obtained for a Reynolds number range of 700-3400 and total temperature difference and pressure drop values are compared with ETU HEX. A new plate (Plate2) with corrugation pattern using smaller amplitude is designed and analyzed. The thermal properties are in good agreement with experimental data for the commercial plate. For the new plate, the decrease of the amplitude leads to a smaller enlargement factor which causes a low heat transfer rate while the pressure drop remains almost constant. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Amer Soc Mechanical Engineers | en_US |
dc.relation.ispartof | Proceedings Of The ASME 12Th Biennial Conference On Engineering Systems Design And Analysis | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Wavy Ducts | en_US |
dc.subject | Flow | en_US |
dc.title | Cfd Aided Design of Heat Transfer Plates for Gasketed Plate Heat Exchangers | en_US |
dc.type | Conference Object | en_US |
dc.department | Faculties, Faculty of Engineering, Department of Mechanical Engineering | en_US |
dc.department | Fakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümü | tr_TR |
dc.identifier.volume | 3 | |
dc.authorid | 0000-0002-2034-0008 | - |
dc.identifier.wos | WOS:000361407000024 | en_US |
dc.identifier.scopus | 2-s2.0-84916894617 | en_US |
dc.institutionauthor | Kakaç, Sadık | - |
dc.institutionauthor | Aradağ, Selin | - |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
item.openairetype | Conference Object | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | 02.7. Department of Mechanical Engineering | - |
Appears in Collections: | Makine Mühendisliği Bölümü / Department of Mechanical Engineering Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
WEB OF SCIENCETM
Citations
1
checked on Aug 31, 2024
Page view(s)
102
checked on Dec 23, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.