Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/2790
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAydın, M. Akif-
dc.contributor.authorKılıç, Sadık Engin-
dc.contributor.authorErgün, Arif Şanlı-
dc.contributor.authorBozkurt, Ayhan-
dc.contributor.authorDeveci, Erdem-
dc.date.accessioned2019-12-25T14:03:38Z-
dc.date.available2019-12-25T14:03:38Z-
dc.date.issued2016
dc.identifier.citationAydin, M. A., Kilinc, M. S., Ergun, A. S., Bozkurt, A., and Deveci, E. (2016, September). Ultrasonic transmittance of rat skull as a function of frequency. In 2016 IEEE International Ultrasonics Symposium (IUS) (pp. 1-4). IEEE.en_US
dc.identifier.isbn978-1-4673-9897-8
dc.identifier.issn1948-5719
dc.identifier.urihttps://hdl.handle.net/20.500.11851/2790-
dc.identifier.urihttps://ieeexplore.ieee.org/document/7728799-
dc.description.abstractThe applications of focused ultrasound in the brain have the common obstacle of penetrating the skull. The purpose of this study is to characterize the ultrasonic transmittance of the rat skull, which is the common animal model used in clinical studies. We modeled the skull as an acoustic cavity and derived an expression for the ultrasonic transmittance that takes into account the multiple reflections in the skull. We built an experimental setup with which we measured the ultrasonic transmittance. By using XYZ scanner, focused transducers and a hydrophone, we obtained ultrasonic transmission images of ex-vivo rat skulls. We found these images to be consistent with the anatomical structure. We also measured the transmittance frequency response of the rat skulls. We observed interference patterns in frequency responses which is consistent with the acoustical cavity model we proposed. We observed relatively high transmittance at frequencies where the multiple reflections add up constructively, whereas we observed relatively low transmittance otherwise.en_US
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.ispartof2016 IEEE International Ultrasonics Symposium (IUS)en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBrainen_US
dc.subjectrat skullen_US
dc.subjectfocused ultrasounden_US
dc.titleUltrasonic Transmittance of Rat Skull as a Function of Frequencyen_US
dc.typeConference Objecten_US
dc.departmentFaculties, Faculty of Engineering, Department of Electrical and Electronics Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Elektrik ve Elektronik Mühendisliği Bölümütr_TR
dc.authorid0000-0002-6193-5761-
dc.identifier.wosWOS:000387497400426en_US
dc.identifier.scopus2-s2.0-84996565835en_US
dc.institutionauthorErgün, Arif Şanlı-
dc.identifier.doi10.1109/ULTSYM.2016.7728799-
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.identifier.scopusquality--
item.openairetypeConference Object-
item.languageiso639-1en-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
Appears in Collections:Elektrik ve Elektronik Mühendisliği Bölümü / Department of Electrical & Electronics Engineering
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

1
checked on Dec 21, 2024

Page view(s)

46
checked on Dec 23, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.