Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/2790
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Aydın, M. Akif | - |
dc.contributor.author | Kılıç, Sadık Engin | - |
dc.contributor.author | Ergün, Arif Şanlı | - |
dc.contributor.author | Bozkurt, Ayhan | - |
dc.contributor.author | Deveci, Erdem | - |
dc.date.accessioned | 2019-12-25T14:03:38Z | - |
dc.date.available | 2019-12-25T14:03:38Z | - |
dc.date.issued | 2016 | |
dc.identifier.citation | Aydin, M. A., Kilinc, M. S., Ergun, A. S., Bozkurt, A., and Deveci, E. (2016, September). Ultrasonic transmittance of rat skull as a function of frequency. In 2016 IEEE International Ultrasonics Symposium (IUS) (pp. 1-4). IEEE. | en_US |
dc.identifier.isbn | 978-1-4673-9897-8 | |
dc.identifier.issn | 1948-5719 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11851/2790 | - |
dc.identifier.uri | https://ieeexplore.ieee.org/document/7728799 | - |
dc.description.abstract | The applications of focused ultrasound in the brain have the common obstacle of penetrating the skull. The purpose of this study is to characterize the ultrasonic transmittance of the rat skull, which is the common animal model used in clinical studies. We modeled the skull as an acoustic cavity and derived an expression for the ultrasonic transmittance that takes into account the multiple reflections in the skull. We built an experimental setup with which we measured the ultrasonic transmittance. By using XYZ scanner, focused transducers and a hydrophone, we obtained ultrasonic transmission images of ex-vivo rat skulls. We found these images to be consistent with the anatomical structure. We also measured the transmittance frequency response of the rat skulls. We observed interference patterns in frequency responses which is consistent with the acoustical cavity model we proposed. We observed relatively high transmittance at frequencies where the multiple reflections add up constructively, whereas we observed relatively low transmittance otherwise. | en_US |
dc.language.iso | en | en_US |
dc.publisher | IEEE | en_US |
dc.relation.ispartof | 2016 IEEE International Ultrasonics Symposium (IUS) | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Brain | en_US |
dc.subject | rat skull | en_US |
dc.subject | focused ultrasound | en_US |
dc.title | Ultrasonic Transmittance of Rat Skull as a Function of Frequency | en_US |
dc.type | Conference Object | en_US |
dc.department | Faculties, Faculty of Engineering, Department of Electrical and Electronics Engineering | en_US |
dc.department | Fakülteler, Mühendislik Fakültesi, Elektrik ve Elektronik Mühendisliği Bölümü | tr_TR |
dc.authorid | 0000-0002-6193-5761 | - |
dc.identifier.wos | WOS:000387497400426 | en_US |
dc.identifier.scopus | 2-s2.0-84996565835 | en_US |
dc.institutionauthor | Ergün, Arif Şanlı | - |
dc.identifier.doi | 10.1109/ULTSYM.2016.7728799 | - |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopusquality | - | - |
item.openairetype | Conference Object | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
Appears in Collections: | Elektrik ve Elektronik Mühendisliği Bölümü / Department of Electrical & Electronics Engineering Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
1
checked on Dec 21, 2024
Page view(s)
46
checked on Dec 23, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.