Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/2867
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPramuanjaroenkij, Anchasa-
dc.contributor.authorPhankhoksoong, Siriluk-
dc.contributor.authorTongkratoke, Amarin-
dc.contributor.authorKakaç, Sadık-
dc.date.accessioned2019-12-25T14:04:30Z-
dc.date.available2019-12-25T14:04:30Z-
dc.date.issued2018
dc.identifier.citationPramuanjaroenkij, A., Phankhoksoong, S., Tongkratoke, A., and Kakac, S. (2018). THE EXPERIMENTAL INVESTIGATION OF A DOUBLE PIPE HEAT EXCHANGER INSTALLED INSIDE A SPLIT-TYPE AIR-CONDITIONING SYSTEM. In International Heat Transfer Conference Digital Library. Begel House Inc..en_US
dc.identifier.issn2377424X
dc.identifier.urihttps://hdl.handle.net/20.500.11851/2867-
dc.identifier.urihttp://ihtcdigitallibrary.com/conferences/ihtc16,11a67ae211c8baf5,0ceaacf4220ace9c.html-
dc.description16th International Heat Transfer Conference, IHTC (2018: Beijing, China)
dc.description.abstractThis research aimed to study effects of a double-pipe heat exchanger which installed inside a 24000-BTUh split-type air-conditioning (A/C) system. The heat exchanger was used to exchange heat between low temperature refrigerant inside the suction line (the refrigerant tube between the evaporator and the compressor) and high temperature refrigerant inside the liquid line (the refrigerant tube between the receiver tank and the refrigerant flow control valve). The A/C power consumptions with and without the heat exchanger installed were measured. This study also investigated the A/C power consumptions when the A/C system was applied with the heat exchanger coupled with fabric drying application which induced the evaporative heat transfer effect at the condensing unit in 4 different weather conditions; the normal and rainy daytime and nighttime. From the experimental results, the A/C system with the heat exchanger consumed power less than the system without the heat exchanger in all weather conditions. Remarkably, during the nighttime, the A/C system with the heat exchanger consumed power notably less than that of the system without the heat exchanger. The A/C system with the heat exchanger coupled with the drying application consumed power less than that of the system without the heat exchanger but with the drying application in all weather conditions. © 2018 International Heat Transfer Conference. All rights reserved.en_US
dc.description.sponsorshipThe research described in this paper was financially supported by Faculty of Science and Engineering and Office of Campus, Kasetsart University, Chalermphrakiat Sakon Nakhon Province Campus, Kasetsart University Research and Development Institute, Kasetsart University, Turkish Academic of Science and TOBB University of Economics and Technology.
dc.language.isoenen_US
dc.publisherBegell House Inc.en_US
dc.relation.ispartof16th International Heat Transfer Conference, IHTCen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectHeat exchangers en_US
dc.subjectheat transfer en_US
dc.subjectcorrugated plateen_US
dc.titleThe Experimental Investigation of a Double Pipe Heat Exchanger Installed Inside a Split-Type Air-Conditioning Systemen_US
dc.typeConference Objecten_US
dc.relation.ispartofseriesInternational Heat Transfer Conferenceen_US
dc.departmentFaculties, Faculty of Engineering, Department of Mechanical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümütr_TR
dc.identifier.volume2018
dc.identifier.startpage4823
dc.identifier.endpage4832
dc.authorid0000-0002-7839-8034-
dc.identifier.scopus2-s2.0-85068351549en_US
dc.institutionauthorKakaç, Sadık-
dc.identifier.doi10.1615/IHTC16.her.023628-
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.identifier.scopusquality--
item.openairetypeConference Object-
item.languageiso639-1en-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.author.dept02.7. Department of Mechanical Engineering-
Appears in Collections:Makine Mühendisliği Bölümü / Department of Mechanical Engineering
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Show simple item record



CORE Recommender

Page view(s)

94
checked on Dec 23, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.