Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/2892
Title: | Determination of initial electron parameters by means of Monte Carlo simulations for the Siemens Artiste Linac 6 MV photon beam | Authors: | Tuğrul, Taylan Eroğul, Osman |
Keywords: | Monte Carlo Simulation BEAMnrc DOSXYZnrc Artiste |
Publisher: | Greater Poland Cancer Centre | Source: | Tuğrul, T., & Eroğul, O. (2019). Determination of initial electron parameters by means of Monte Carlo simulations for the Siemens Artiste Linac 6 MV photon beam. Reports of Practical Oncology & Radiotherapy, 24(4), 331-337. | Abstract: | Aim: In this study, we investigated initial electron parameters of Siemens Artiste Linac with 6 MV photon beam using the Monte Carlo method. Background: It is essential to define all the characteristics of initial electrons hitting the target, i.e. mean energy and full width of half maximum (FWHM)of the spatial distribution intensity, which is needed to run Monte Carlo simulations. The Monte Carlo is the most accurate method for simulation of radiotherapy treatments. Materials and methods: Linac head geometry was modeled using the BEAMnrc code. The phase space files were used as input file to DOSXYZnrc simulation to determine the dose distribution in a water phantom. We obtained percent depth dose curves and the lateral dose profile. All the results were obtained at 100 cm of SSD and for a 10 × 10 cm2 field. Results: We concluded that there existed a good conformity between Monte Carlo simulation and measurement data when we used electron mean energy of 6.3 MeV and 0.30 cm FWHM value as initial parameters. We observed that FWHM values had very little effect on PDD and we found that the electron mean energy and FWHM values affected the lateral dose profile. However, these effects are between tolerance values. Conclusions: The initial parameters especially depend on components of a linac head. The phase space file which was obtained from Monte Carlo Simulation for a linac can be used as calculation of scattering, MLC leakage, to compare dose distribution on patients and in various studies. | URI: | https://hdl.handle.net/20.500.11851/2892 https://doi.org/10.1016/j.rpor.2019.05.002 |
ISSN: | 1507-1367 |
Appears in Collections: | Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
5
checked on Nov 2, 2024
WEB OF SCIENCETM
Citations
12
checked on Nov 2, 2024
Page view(s)
86
checked on Nov 4, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.