Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/3684
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Özgüzar, Hatice Ferda | - |
dc.contributor.author | Can, Gizem Kaleli | - |
dc.contributor.author | Kabay, Gözde | - |
dc.contributor.author | Mutlu, Mehmet | - |
dc.date.accessioned | 2020-09-17T14:43:36Z | - |
dc.date.available | 2020-09-17T14:43:36Z | - |
dc.date.issued | 2019-06 | |
dc.identifier.citation | Özgüzar, H. F., Can, G. K., Kabay, G., & Mutlu, M. (2019). Quartz tuning fork as a mass sensitive biosensor platform with a bi-layer film modification via plasma polymerization. MRS Communications, 9(2), 710-718. | en_US |
dc.identifier.issn | 2159-6859 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11851/3684 | - |
dc.identifier.uri | https://doi.org/10.1557/mrc.2019.55 | - |
dc.description.abstract | Due to the lack of the stability of amine films, a promising transducer, quartz-tuning fork (QTF) prongs were modified by a bi-layer film of plasma-polymerized n-heptane (hep) and then by ethylenediamine (EDA), respectively. For this purpose, the authors investigate the stability of amine-rich thin films both in air and aqueous medium. EDA films were deposited on QTF substrates by using an RF plasma system. The final amine-rich thin film was used to immobilize biologic recognition element. Model protein studies were showed that selected thin films could be adapted to QTF transducers to be used as a biosensor template. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Cambridge University Press | en_US |
dc.relation.ispartof | MRS Communications | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Surface Modification | en_US |
dc.subject | Microscopy | en_US |
dc.subject | Allylamine | en_US |
dc.subject | Stability | en_US |
dc.subject | Ethylene | en_US |
dc.subject | Contact | en_US |
dc.subject | Improve | en_US |
dc.subject | Oxygen | en_US |
dc.title | Quartz Tuning Fork as a Mass Sensitive Biosensor Platform With a Bi-Layer Film Modification Via Plasma Polymerization | en_US |
dc.type | Article | en_US |
dc.department | Faculties, Faculty of Engineering, Department of Biomedical Engineering | en_US |
dc.department | Fakülteler, Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümü | tr_TR |
dc.identifier.volume | 9 | |
dc.identifier.issue | 2 | |
dc.identifier.startpage | 710 | |
dc.identifier.endpage | 718 | |
dc.authorid | 0000-0001-7146-1937 | - |
dc.identifier.wos | WOS:000477661800033 | en_US |
dc.identifier.scopus | 2-s2.0-85065437252 | en_US |
dc.institutionauthor | Mutlu, Mehmet | - |
dc.identifier.doi | 10.1557/mrc.2019.55 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopusquality | Q2 | - |
item.openairetype | Article | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | 02.2. Department of Biomedical Engineering | - |
Appears in Collections: | Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
3
checked on Dec 21, 2024
WEB OF SCIENCETM
Citations
8
checked on Dec 21, 2024
Page view(s)
62
checked on Dec 23, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.