Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/4119
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPramuanjaroenkij, Anchasa-
dc.contributor.authorBunta, J.-
dc.contributor.authorPhankhoksoong, S.-
dc.contributor.authorKakaç, Sadık-
dc.date.accessioned2021-01-27T13:45:02Z-
dc.date.available2021-01-27T13:45:02Z-
dc.date.issued2019-06
dc.identifier.citationPramuanjaroenkij, A., Bunta, J., Phankhoksoong, S., and Kakac, S. (2019). A temperature distribution study in a heated bed component made from butyl rubber for dust mite allergy patients. Journal of Research and Applications in Mechanical Engineering, 7(1), 71-82.en_US
dc.identifier.issn2229-2152
dc.identifier.issn2697-424x
dc.identifier.urihttps://hdl.handle.net/20.500.11851/4119-
dc.identifier.urihttps://ph01.tci-thaijo.org/index.php/jrame/article/view/187401-
dc.description.abstractAsthma is one of many respiratory tract diseases and can be caused by allergy symptoms. Allergy symptoms can be stimulated by many substances, dust mites are among them. Dust-mite feces can trick the allergy symptom in the patients. Allergy significantly affect quality of patient life. Environment surrounded the dust-mite allergy patients should be controlled to reduce a number of dust mites, the dust mites cannot survive in places where temperature is above 60°C and more than 45 min. This work focused on investigating temperature distributions on a heated mattress component made from butyl rubber, numerically and experimentally. Results were used to evaluate possibility to fabricate dust-mite-free bedding components using butyl rubber since mattress and pillow can be homes of million dust mites. The component was designed by computer aided design (CAD) based on a hospital-bed-mattress shape. The component was also designed to be fed with hot water to heat its surface temperature up to the unacceptable living conditions of dust mites. The component was fabricated locally by using recycle butyl rubber sheets. From simulation results with the flow rate of hot water inlet at 6.69×10-5 m3/s and 100°C, temperature distributions of the surface could be maintained above 60 °C throughout 45 min. Experimental results at the approximate inlet flow rate showed that temperature distributions of the component surface were also above 60°C for the same duration. Therefore, both results showed potentials of the design to be developed as the dust-mite-free bedding components to help creating dust-mite-free environments for the dust-mite allergy patients.en_US
dc.language.isoenen_US
dc.publisherTSMEen_US
dc.relation.ispartofJournal of Research and Applications in Mechanical Engineeringen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDust Miteen_US
dc.subjectAllergyen_US
dc.subjectBedding Componenten_US
dc.subjectHeat Transferen_US
dc.subjectFluid Flowen_US
dc.titleA Temperature Distribution Study in a Heated Bed Component Made From Butyl Rubber for Dust Mite Allergy Patientsen_US
dc.typeArticleen_US
dc.departmentFaculties, Faculty of Engineering, Department of Mechanical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümütr_TR
dc.identifier.volume7
dc.identifier.issue1
dc.identifier.startpage71
dc.identifier.endpage82
dc.authorid0000-0002-7839-8034-
dc.institutionauthorKakaç, Sadık-
dc.identifier.doi10.14456/jrame.2019.7-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
item.openairetypeArticle-
item.languageiso639-1en-
item.grantfulltextopen-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.author.dept02.7. Department of Mechanical Engineering-
Appears in Collections:Makine Mühendisliği Bölümü / Department of Mechanical Engineering
Files in This Item:
File Description SizeFormat 
KakacS_TEMPERATURE.pdf1.65 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

168
checked on Dec 23, 2024

Download(s)

74
checked on Dec 23, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.