Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/6278
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ergun, A. Sanli | - |
dc.date.accessioned | 2021-09-11T15:35:36Z | - |
dc.date.available | 2021-09-11T15:35:36Z | - |
dc.date.issued | 2011 | en_US |
dc.identifier.issn | 0041-624X | - |
dc.identifier.issn | 1874-9968 | - |
dc.identifier.uri | https://doi.org/10.1016/j.ultras.2011.03.006 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.11851/6278 | - |
dc.description.abstract | Focused ultrasound therapy relies on acoustic power absorption by tissue. The stronger the absorption the higher the temperature increase is. However, strong acoustic absorption also means faster attenuation and limited penetration depth. Hence, there is a trade-off between heat generation efficacy and penetration depth. In this paper, we formulated the acoustic power absorption as a function of frequency and attenuation coefficient, and defined two figures of merit to measure the power absorption: spatial peak of the acoustic power absorption density, and the acoustic power absorbed within the focal area. Then, we derived "rule of thumb'' expressions for the optimum frequencies that maximized these figures of merit given the target depth and homogeneous tissue type. We also formulated a method to calculate the optimum frequency for inhomogeneous tissue given the tissue composition for situations where the tissue structure can be assumed to be made of parallel layers of homogeneous tissue. We checked the validity of the rules using linear acoustic field simulations. For a one-dimensional array of 4 cm acoustic aperture, and for a two-dimensional array of 4 x 4 cm(2) acoustic aperture, we found that the power absorbed within the focal area is maximized at 0.86 MHz, and 0.79 MHz, respectively, when the target depth is 4 cm in muscle tissue. The rules on the other hand predicted the optimum frequencies for acoustic power absorption as 0.9 MHz and 0.86 MHz, respectively for the 1D and 2D array case, which are within 6% and 9% of the field simulation results. Because radiation force generated by an acoustic wave in a lossy propagation medium is approximately proportional to the acoustic power absorption, these rules can be used to maximize acoustic radiation force generated in tissue as well. (C) 2011 Elsevier B.V. All rights reserved. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartof | Ultrasonics | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | High intensity focused ultrasound | en_US |
dc.subject | HIFU | en_US |
dc.subject | FUS | en_US |
dc.subject | Acoustic radiation force | en_US |
dc.subject | FUS frequency optimization | en_US |
dc.title | Analytical and numerical calculations of optimum design frequency for focused ultrasound therapy and acoustic radiation force | en_US |
dc.type | Article | en_US |
dc.department | Faculties, Faculty of Engineering, Department of Electrical and Electronics Engineering | en_US |
dc.department | Fakülteler, Mühendislik Fakültesi, Elektrik ve Elektronik Mühendisliği Bölümü | tr_TR |
dc.identifier.volume | 51 | en_US |
dc.identifier.issue | 7 | en_US |
dc.identifier.startpage | 786 | en_US |
dc.identifier.endpage | 794 | en_US |
dc.identifier.wos | WOS:000291199600002 | en_US |
dc.identifier.scopus | 2-s2.0-79957986857 | en_US |
dc.institutionauthor | Sanlı Ergün, Arif | - |
dc.identifier.pmid | 21459399 | en_US |
dc.identifier.doi | 10.1016/j.ultras.2011.03.006 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopusquality | Q1 | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.fulltext | No Fulltext | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
Appears in Collections: | Elektrik ve Elektronik Mühendisliği Bölümü / Department of Electrical & Electronics Engineering PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
12
checked on Nov 16, 2024
WEB OF SCIENCETM
Citations
9
checked on Aug 31, 2024
Page view(s)
36
checked on Nov 11, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.