Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/7084
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Asliyuce, Sevgi | - |
dc.contributor.author | Uzun, Lokman | - |
dc.contributor.author | Rad, Abbas Yousefi | - |
dc.contributor.author | Ünal, Serhat | - |
dc.contributor.author | Say, Ridvan | - |
dc.contributor.author | Denizli, Adil | - |
dc.date.accessioned | 2021-09-11T15:45:26Z | - |
dc.date.available | 2021-09-11T15:45:26Z | - |
dc.date.issued | 2012 | en_US |
dc.identifier.issn | 1570-0232 | - |
dc.identifier.uri | https://doi.org/10.1016/j.jchromb.2012.02.001 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.11851/7084 | - |
dc.description.abstract | In the present study, we have focused our attention to prepare molecular imprinted composite cryogel membranes for purification of hepatitis B surface antibody (anti-HBs) by fast protein liquid chromatography. Before the preparation of the molecular imprinted composite cryogel membranes (MI-CMs) by free radical polymerization at sub-zero temperature, we have synthesized and characterized the anti-HBs imprinted particles. Then, the cryogel membranes (CMs) were characterized by swelling test, scanning electron microscopy and Fourier transform infrared spectroscopy. Prior to chromatographic purification studies, the effective parameters on the anti-HBs adsorption process were evaluated by investigating the dependency of the adsorption capacity on flow-rate, anti-HBs concentration, contact time and ionic strength. The maximum anti-HBs adsorption capacity was calculated as 701.4 mIU/g CM. The selectivity of the MI-CMs was shown by competitive adsorption of anti-HBs, total anti-hepatitis A antibody (anti-HAV) and total immunoglobulin E (IgE) adsorption studies. The MI-CMs have relative selectivity coefficients as 5.45 for anti-HBs/total anti-HAV and 9.05 for anti-HBs/total IgE, respectively. The phosphate buffer solution (pH 7.4) containing 1.0 M NaCl was used for elution, almost completely, of adsorbed anti-HBs molecules. The MI-CMs could be used many times without any significant decrease in the adsorption capacity. The chromatographic purification performances of the MI-CMs were also investigated. The chromatographic parameters such as capacity and separation factors, the theoretical plate number and resolution of the MI-CMs were calculated as 5.48, 6.02, 1153.9, and 1.72 for anti-HBs molecules, respectively. As a conclusion, we can say that the MI-CMs could be used for specific purification of anti-HBs from anti-HBs positive human plasma. (C) 2012 Elsevier B.V. All rights reserved. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Science Bv | en_US |
dc.relation.ispartof | Journal of Chromatography B-Analytical Technologies In The Biomedical And Life Sciences | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Molecular imprinted polymers | en_US |
dc.subject | Anti-hepatitis B surface antibody | en_US |
dc.subject | Composite cryogel membrane | en_US |
dc.subject | Fast protein liquid chromatography | en_US |
dc.subject | Affinity purification | en_US |
dc.title | Molecular Imprinting Based Composite Cryogel Membranes for Purification of Anti-Hepatitis B Surface Antibody by Fast Protein Liquid Chromatography | en_US |
dc.type | Article | en_US |
dc.department | Faculties, School of Medicine, Department of Internal Medical Sciences | en_US |
dc.department | Fakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü | tr_TR |
dc.identifier.volume | 889 | en_US |
dc.identifier.startpage | 95 | en_US |
dc.identifier.endpage | 102 | en_US |
dc.authorid | 0000-0003-1184-4711 | - |
dc.authorid | 0000-0003-0002-0856 | - |
dc.authorid | 0000-0002-3971-7725 | - |
dc.identifier.wos | WOS:000302452600014 | en_US |
dc.identifier.scopus | 2-s2.0-84858299048 | en_US |
dc.institutionauthor | Yousefi-Rad, Abbas | - |
dc.identifier.pmid | 22382092 | en_US |
dc.identifier.doi | 10.1016/j.jchromb.2012.02.001 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopusquality | Q1 | - |
item.openairetype | Article | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
Appears in Collections: | Dahili Tıp Bilimleri Bölümü / Department of Internal Medical Sciences PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
62
checked on Dec 21, 2024
WEB OF SCIENCETM
Citations
64
checked on Oct 26, 2024
Page view(s)
50
checked on Dec 23, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.