Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/8716
Title: | Effects of Static Cyclotorsion Compensation of Refractive\routcomes and Level of Vision in Excimer Laser Surgery | Authors: | Ozulken, Kemal Cubuk, Mehmet Ozgur Yuksel, Erdem |
Keywords: | Göz Hastalıkları | Source: | Ozulken, K., Cubuk, M. O., & Yuksel, E. (2021). Effects of Static Cyclotorsion Compensation of Refractive Outcomes and Level of Vision in Excimer Laser Surgery. Glokom-Katarakt/Journal of Glaucoma-Cataract, 16(1). | Abstract: | Purpose: To evaluate the reliability and reproducibility of static cyclotorsion compensation (SCC) measurements made by software of\rWaveLight EX500 Excimer laser in patients undergoing Laser-Assisted in Situ Keratomileusis (LASIK) procedure.\rMaterials and Methods: A retrospective study was designed to compare the refractive and visual outcomes of LASIK procedure with or\rwithout SCC. Patients with astigmatism greater than or equal to 0.50 D that undergone LASIK surgery with SCC were included in the Group\r1, without SCC were included in Group 2. The astigmatism of eyes in group 1 was also classifi ed according to axis as with the rule (WTR),\ragainst the rule (ATR) and oblique. The preoperative and postoperative spherical error, astigmatic error, and axis of astigmatism were compared\rbetween different groups. Subgroup analysis of group 1 was performed between different types of astigmatism groups.\rResults: Three hundred ninety-eight eyes of 199 patients were included in Group 1 and 126 eyes of 63 patients were included in Group 2.\rPostoperative spherical error was -0.003±0.36 (-1.00 +1.50) in group 1 and +0.11± 0.65 (-0.75 +1.50) in group 2 (p=0.04), Postoperative\rastigmatic error was -0.40±0.22 (-1.25 +0.50) in group 1 and -0.85± 0.22 (-1.25 -0.50) in group 2, (p=0.001). The mean magnitude of SCC\rwas -0.95°±4.1. Postoperative astigmatic error was signifi cantly higher in WTR than ATR and oblique group (p=0.044, p=0.039, respectively)\rConclusion: The cyclotorsion is reasonably compensated with using software of WaveLight EX500 Excimer in conjunction with the Wavelight\rTopolyzer Vario. Refractive outcomes could be better in the oblique group | URI: | https://doi.org/10.37844/glauc.cat.2021.16.7 [TRDIZIN-Document Link-BELIRLENECEK-5] |
ISSN: | 1305-9173 2717-7157 |
Appears in Collections: | TR Dizin İndeksli Yayınlar / TR Dizin Indexed Publications Collection |
Show full item record
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.