Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/8723
Full metadata record
DC FieldValueLanguage
dc.contributor.authorErdem, Onur-
dc.contributor.authorAy, Musa-
dc.contributor.authorYalcin, Asena-
dc.contributor.authorBilgic, Sadik-
dc.contributor.authorSanlidilek, Umman-
dc.contributor.authorAmasyalı, Basri-
dc.contributor.authorSancak, Tanzer-
dc.date.accessioned2022-07-30T16:47:37Z-
dc.date.available2022-07-30T16:47:37Z-
dc.date.issued2022-
dc.identifier.citationErdem, O., Ay, M., Yalcin, A., Bilgic, S., Sanlıdilek, U., Amasyalı, B., ... & Olgar, T. (2022). Patient and Staff Doses for Various Interventional Radiology and Cardiology Examinations in Turkey. Radiation Protection Dosimetry, 198(3), 158-166.en_US
dc.identifier.issn0144-8420-
dc.identifier.issn1742-3406-
dc.identifier.urihttps://doi.org/10.1093/rpd/ncac006-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/8723-
dc.description.abstractThis study aims to determine the radiation doses of patients and staff during different interventional radiology and cardiology examinations. Dose measurements for interventional radiology examinations were performed in Ibn-i Sina Hospital of Ankara University using Siemens Artis-Zee medical imaging system. Patient dose measurement was carried out for interventional cardiology examinations in Cardiology Department of TOBB-ETU University, Medical Faculty Hospital using Philips Allura Centron interventional X-ray system. Patient doses were obtained in terms of kerma area product (KAP) and cumulative air kerma (CAK) from KAP meter attached to the angiography system. Performance tests of the angiography system were performed before patient dose measurements. Staff dose measurements were carried out with thermoluminescence dosimeters (TLD-100) placed in certain areas on the staff. Patient dose measurements were performed for 15 different interventional radiology examinations on a total of 431 patients and for four different cardiology examinations on a total of 299 patients. Monte Carlo based PCXMC 2.0 program was used to calculate patient effective doses. Lower extremity arteriography was the most common examination with a mean KAP value of 30 Gy cm(2) and mean effective dose value of 1.2 mSv for total number of 194 patients. Mean KAP values calculated for coronary angiography, percutaneous coronary intervention, electrophysiological procedures and radiofrequency cardiac ablation examinations were 62.8, 162.8, 16.7 and 70.6 Gy cm(2), respectively. Radiologist, nurse and technician effective dose normalised to the unit KAP of patient dose were 0.15, 0.11 and 0.14 mu Sv Gy(-1) cm(-2). Similarly, cardiologist, nurse and technician effective dose normalised to the unit KAP of patient dose were 0.22, 0.15 and 0.09 mu Sv Gy(-1) cm(-2). Measured KAP and CAK values vary depending on the type and complexity of the examination. The measured staff doses during cardiac examinations were higher when compared with that measured for interventional radiology as expected.en_US
dc.language.isoenen_US
dc.publisherOxford Univ Pressen_US
dc.relation.ispartofRadiation Protection Dosimetryen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDiagnostic Reference Levelsen_US
dc.subjectAir-Kermaen_US
dc.subjectArea Producten_US
dc.subjectRadiationen_US
dc.subjectSkinen_US
dc.titlePatient and Staff Doses for Various Interventional Radiology and Cardiology Examinations in Turkeyen_US
dc.typeArticleen_US
dc.departmentFakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.departmentFaculties, School of Medicine, Department of Internal Medical Sciencesen_US
dc.identifier.volume198en_US
dc.identifier.issue3en_US
dc.identifier.startpage158en_US
dc.identifier.endpage166en_US
dc.identifier.wosWOS:000764634800001en_US
dc.identifier.scopus2-s2.0-85126830180en_US
dc.institutionauthorAmasyalı, Basri-
dc.institutionauthorSancak, İbrahim Tanzer-
dc.identifier.pmid35165744en_US
dc.identifier.doi10.1093/rpd/ncac006-
dc.authorscopusid57225410397-
dc.authorscopusid57541742200-
dc.authorscopusid57201885801-
dc.authorscopusid57560834000-
dc.authorscopusid57559512700-
dc.authorscopusid57559727900-
dc.authorscopusid6602127558-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ3-
item.openairetypeArticle-
item.languageiso639-1en-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.author.dept03.14. Department of Internal Medicine-
Appears in Collections:Dahili Tıp Bilimleri Bölümü / Department of Internal Medical Sciences
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

Page view(s)

176
checked on Dec 23, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.