Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/893
Title: | Investigation of toggling effect on pullout performance of pedicle screws | Authors: | Aycan, Mehmet Fatih Yaman, Mesut Emre Usta, Yusuf Demir, Teyfik Tolunay, Tolga |
Keywords: | expandable polyetheretherketone shell pullout strength Toggling bovine vertebra pedicle screw polyurethane foam |
Publisher: | SAGE Publications Ltd | Source: | Aycan, M. F., Yaman, M. E., Usta, Y., Demir, T., & Tolunay, T. (2018). Investigation of toggling effect on pullout performance of pedicle screws. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 232(4), 395-402. | Abstract: | Objective of this study is to assess the pullout performance of various pedicle screws in different test materials after toggling tests comparatively. Solid core, cannulated (cemented), novel expandable and solid-core (cemented) pedicle screws were instrumented to the polyurethane foams (Grade 10 and Grade 40) produced in laboratory and bovine vertebra. ASTM F543 standard was used for preparation process of samples. Toggling tests were carried out. After toggling test procedures, pullout tests were performed. Load versus displacement graph was recorded, and the ultimate pullout force was defined as the maximum load (pullout strength) sustained before failure of screw. Anteriosuperior and oblique radiographs were taken from each sample after instrumentation in order to examine screw placement and cement distribution. The pullout strength of pedicle screws decreased after toggling tests with respect to the initial condition. While the cemented solid-core pedicle screws had the highest pullout strength in all test materials, they had the highest strength differences. The cemented solid-core pedicle screws had decrement rates of 27% and 16% in Grade 10 and Grade 40, respectively. There are almost same decrement rate (between 5.5% and 6.5%) for all types of pedicle screws instrumented to the samples of bovine vertebra. The pullout strengths of novel expandable pedicle screws in both of early period and after toggling conditions were almost similar, in other words, the decrement rates of it were lower than other types. According to the data collected from this study, polymethylmethacrylate augmentation significantly decreases pullout strength following the toggling loads. Higher brittleness of cured polymethylmethacrylate has adverse effect on the pullout strength. Although augmentation is an important process for enhancing pullout strength in early period, it has some disadvantages for preserving stabilization in a long time. Expandable pedicle screw with polyetheretherketone shell may be good alternative to polymethylmethacrylate augmentation on both primer stabilization and long-term loading application with toggling. | URI: | https://doi.org/10.1177/0954411918755417 https://hdl.handle.net/20.500.11851/893 |
ISSN: | 0954-4119 |
Appears in Collections: | Makine Mühendisliği Bölümü / Department of Mechanical Engineering PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
5
checked on Nov 2, 2024
WEB OF SCIENCETM
Citations
10
checked on Nov 2, 2024
Page view(s)
74
checked on Nov 4, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.