Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/896
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Özalp, Hakan | - |
dc.contributor.author | Özkaya, Mustafa | - |
dc.contributor.author | Yaman, Onur | - |
dc.contributor.author | Demir, Teyfik | - |
dc.date.accessioned | 2019-03-29T13:51:34Z | |
dc.date.available | 2019-03-29T13:51:34Z | |
dc.date.issued | 2018-04-01 | |
dc.identifier.citation | Özalp, H., Özkaya, M., Yaman, O., & Demir, T. (2018). Biomechanical comparison of transdiscal fixation and posterior fixation with and without transforaminal lumbar interbody fusion in the treatment of L5–S1 lumbosacral joint. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 232(4), 371-377. | en_US |
dc.identifier.issn | 0954-4119 | |
dc.identifier.uri | https://doi.org/10.1177/0954411918760959 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.11851/896 | - |
dc.description.abstract | Transdiscal screw fixation is generally performed in the treatment of high-grade L5–S1 spondylolisthesis. The main thought of the study is that the biomechanical performances of the transdiscal pedicle screw fixation can be identical to standard posterior pedicle screw fixations with or without transforaminal lumbar interbody fusion cage insertion. Lumbosacral portions and pelvises of 45 healthy lambs’ vertebrae were dissected. Animal cadavers were randomly and equally divided into three groups for instrumentation. Three fixation systems, L5–S1 posterior pedicle screw fixation, L5–S1 posterior pedicle screw fixation with transforaminal lumbar interbody fusion cage insertion, and L5–S1 transdiscal pedicle screw fixation, were generated. Axial compression, flexion, and torsion tests were conducted on test samples of each system. In axial compression, L5–S1 transdiscal fixation was less stiff than L5–S1 posterior pedicle screw fixation with transforaminal lumbar interbody fusion cage insertion. There were no significant differences between groups in flexion. Furthermore, L5–S1 posterior fixation was stiffest under torsional loads. When axial compression and flexion loads are taken into consideration, transdiscal fixation can be alternatively used instead of posterior pedicle screw fixation in the treatment of L5–S1 spondylolisthesis because it satisfies enough stability. However, in torsion, posterior fixation is shown as a better option due to its higher stiffness. | en_US |
dc.language.iso | en | en_US |
dc.publisher | SAGE Publications Ltd | en_US |
dc.relation.ispartof | Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Transdiscal fixation | en_US |
dc.subject | pedicular transvertebral screw fixation | en_US |
dc.subject | transforaminal lumbar interbody fusion | en_US |
dc.subject | pediculo-body fixation | en_US |
dc.title | Biomechanical Comparison of Transdiscal Fixation and Posterior Fixation With and Without Transforaminal Lumbar Interbody Fusion in the Treatment of L5–s1 Lumbosacral Joint | en_US |
dc.type | Article | en_US |
dc.department | Faculties, Faculty of Engineering, Department of Mechanical Engineering | en_US |
dc.department | Fakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümü | tr_TR |
dc.identifier.volume | 232 | |
dc.identifier.issue | 4 | |
dc.identifier.startpage | 371 | |
dc.identifier.endpage | 377 | |
dc.authorid | Demir, Teyfik [0000-0001-6352-8302] | - |
dc.identifier.wos | WOS:000429916100004 | en_US |
dc.identifier.scopus | 2-s2.0-85045315262 | en_US |
dc.institutionauthor | Demir, Teyfik | - |
dc.identifier.pmid | 29475413 | en_US |
dc.identifier.doi | 10.1177/0954411918760959 | - |
dc.identifier.doi | 10.1177/0954411918760959 | - |
dc.authorscopusid | Demir, Teyfik [3488228600] | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopusquality | Q2 | - |
item.openairetype | Article | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
Appears in Collections: | Makine Mühendisliği Bölümü / Department of Mechanical Engineering PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |