Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/897
Full metadata record
DC FieldValueLanguage
dc.contributor.authorUlutaş, Murat-
dc.contributor.authorÖzkaya, Mustafa-
dc.contributor.authorYaman, Onur-
dc.contributor.authorDemir, Teyfik-
dc.date.accessioned2019-03-29T14:05:27Z
dc.date.available2019-03-29T14:05:27Z
dc.date.issued2018-07-01
dc.identifier.citationUlutaş, M., Özkaya, M., Yaman, O., & Demir, T. (2018). Do we need a transforaminal lumbar interbody fusion cage to increase the stability of functional spinal unit when comparing unilateral and bilateral fixation?. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 232(7), 655-664.en_US
dc.identifier.issn0954-4119
dc.identifier.urihttps://doi.org/10.1177/0954411918783779-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/897-
dc.description.abstractTransforaminal lumbar interbody fusion was an alternative to posterior lumbar interbody fusion for decompression surgeries. This study investigates the biomechanical responses of the unilateral and bilateral pedicle screw fixations with/without transforaminal lumbar interbody fusion cages under axial compression, flexion, and torsional loads. Ovine vertebrae were used in this study. Cadavers, randomly divided into five, were intact control group, bilateral pedicle screw fixation group, bilateral pedicle screw fixation group with transforaminal lumbar interbody fusion cage, unilateral pedicle screw fixation group, and unilateral pedicle screw fixation group with transforaminal lumbar interbody fusion cage. Axial compression, flexion, and torsion tests were performed on specimens. All study groups provided higher stiffness and yield load values than control group under axial compression. Addition of transforaminal lumbar interbody fusion cage to bilateral fixation increased the stiffness under axial compression. Moreover, additional use of transforaminal lumbar interbody fusion in unilateral fixation increased the yield load values under axial compression. Control group was the stiffest in flexion test. Placing a transforaminal lumbar interbody fusion cage to both unilateral and bilateral fixations did not significantly change the stiffness values. Additional transforaminal lumbar interbody fusion cage increased the yield moment of the bilateral fixation. In torsion test, control group had the highest stiffness and yield torque. The facet joints are the most important parts of the vertebrae on the stability. When comparing the bilateral and unilateral fixations with transforaminal lumbar interbody fusion addition, the more facet preserving approach has significantly higher stability under axial compression, flexion, and torsion. Unilateral fixation with transforaminal lumbar interbody fusion cage can be said biomechanically stable and advantageous fixation system because of the advantage on the less facet and soft tissue resection compared to bilateral fixation with transforaminal lumbar interbody fusion.en_US
dc.language.isoenen_US
dc.publisherSAGE Publications Ltden_US
dc.relation.ispartofProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicineen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBilateral fixationen_US
dc.subjectunilateral fixationen_US
dc.subjecttransforaminal lumbar interbody fusionen_US
dc.titleDo We Need a Transforaminal Lumbar Interbody Fusion Cage To Increase the Stability of Functional Spinal Unit When Comparing Unilateral and Bilateral Fixation?en_US
dc.typeArticleen_US
dc.departmentFaculties, Faculty of Engineering, Department of Mechanical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümütr_TR
dc.identifier.volume232
dc.identifier.issue7
dc.identifier.startpage655
dc.identifier.endpage664
dc.authoridDemir, Teyfik [0000-0001-6352-8302]-
dc.identifier.wosWOS:000438608300002en_US
dc.identifier.scopus2-s2.0-85049018014en_US
dc.institutionauthorDemir, Teyfik-
dc.identifier.pmid29923451en_US
dc.identifier.doi10.1177/0954411918783779-
dc.identifier.doi10.1177/0954411918783779-
dc.authorscopusidDemir, Teyfik [3488228600]-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ2-
item.openairetypeArticle-
item.languageiso639-1en-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
Appears in Collections:Makine Mühendisliği Bölümü / Department of Mechanical Engineering
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

WEB OF SCIENCETM
Citations

1
checked on Dec 21, 2024

Page view(s)

64
checked on Dec 23, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.