Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/5622
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÇetinbas, Cankur Fırat-
dc.contributor.authorTuna, B. A.-
dc.contributor.authorAkın, C.-
dc.contributor.authorAradağ, S.-
dc.contributor.authorUzo, N. S.-
dc.date.accessioned2021-09-11T15:19:25Z-
dc.date.available2021-09-11T15:19:25Z-
dc.date.issued2010en_US
dc.identifier.citationASME 2010 10th Biennial Conference on Engineering Systems Design and Analysis, ESDA2010, 12 July 2010 through 14 July 2010, Istanbul, 84828en_US
dc.identifier.isbn9780791849163-
dc.identifier.urihttps://doi.org/10.1115/ESDA2010-24712-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/5622-
dc.description.abstractIn this study, a computer program is developed to design and compare gasketed plate heat exchangers with double pipe heat exchangers. The computer program is coded in MATLAB. The user interface of the program is prepared in MATLAB Guide. The program uses hot and cold fluid properties as input data and calculates the characteristics o gasketed plate heat exchangers and double pipe heat exchangers designed for the given conditions. The outputs for gasketed plate heat exchanger design include number of plates, effective area, total heat transfer coefficient, pressure losses, pumping power and cost, whereas, the outputs for double pipe heat exchanger selection are: pump power, total number of hairpins, effective area, pressure drop, total heat transfer coefficient and cost. Correlations selected from literature are used in the program for the analysis. Water is selected as the working fluid to be able to make the comparison. The program compares the heat exchangers based on cost, effective area, and pumping power. The computer program is also used to understand and compare operational behaviors of these two heat exchangers under different operating conditions. Copyright © 2010 by ASME.en_US
dc.description.sponsorshipASME Turkey Section;Loughborough Universityen_US
dc.language.isoenen_US
dc.relation.ispartofASME 2010 10th Biennial Conference on Engineering Systems Design and Analysis, ESDA2010en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDouble pipe heat exchangersen_US
dc.subjectGasketed plate heat exchangersen_US
dc.subjectHeat exchanger comparisonen_US
dc.titleComparison of gasketed plate heat exchangers with double pipe heat exchangersen_US
dc.typeConference Objecten_US
dc.departmentFaculties, Faculty of Engineering, Department of Mechanical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümütr_TR
dc.identifier.volume2en_US
dc.identifier.startpage643en_US
dc.identifier.endpage651en_US
dc.identifier.scopus2-s2.0-79956142967en_US
dc.institutionauthorAradağ, Selin-
dc.identifier.doi10.1115/ESDA2010-24712-
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.relation.conferenceASME 2010 10th Biennial Conference on Engineering Systems Design and Analysis, ESDA2010en_US
item.cerifentitytypePublications-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeConference Object-
item.fulltextNo Fulltext-
item.grantfulltextnone-
Appears in Collections:Makine Mühendisliği Bölümü / Department of Mechanical Engineering
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Show simple item record



CORE Recommender

Page view(s)

18
checked on Apr 15, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.