Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/1529
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTolunay, Tolga-
dc.contributor.authorBaşgül, Cemile-
dc.contributor.authorDemir, Teyfik-
dc.contributor.authorYaman, Mesut E.-
dc.contributor.authorArslan, Arslan Kağan-
dc.date.accessioned2019-06-26T08:07:05Z
dc.date.available2019-06-26T08:07:05Z
dc.date.issued2015-11
dc.identifier.citationTolunay, T., Başgül, C., Demir, T., Yaman, M. E., & Arslan, A. K. (2015). Pullout performance comparison of pedicle screws based on cement application and design parameters. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 229(11), 786-793.en_US
dc.identifier.issn0954-4119
dc.identifier.urihttps://www.ncbi.nlm.nih.gov/pubmed/26503840-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/1529-
dc.description.abstractPedicle screws are the main fixation devices for certain surgeries. Pedicle screw loosening is a common problem especially for osteoporotic incidents. Cannulated screws with cement augmentation are widely used for that kind of cases. Dual lead dual cored pedicle screw has already given promising pullout values without augmentation. This study concentrates on the usage of dual lead dual core with cement augmentation as an alternative to cannulated and standard pedicle screws with cement augmentation. Five groups (dual lead dual core, normal pedicle screw and cannulated pedicle screw with augmentation, normal pedicle screw, dual lead dual cored pedicle screw) were designed for this study. Healthy bovine vertebrae and synthetic polyurethane foams (grade 20) were used as embedding test medium. Test samples were prepared in accordance with surgical guidelines and ASTM F543 standard testing protocols. Pullout tests were conducted with Instron 3300 testing frame. Load versus displacement values were recorded and maximum pullout loads were stated. The dual lead dual cored pedicle screw with poly-methyl methacrylate augmentation exhibited the highest pullout values, while dual lead dual cored pedicle screw demonstrated similar pullout strength as cannulated pedicle screw and normal pedicle screw with poly-methyl methacrylate augmentation. The dual lead dual cored pedicle screw with poly-methyl methacrylate augmentation can be used for osteoporotic and/or severe osteoporotic patients according to its promising results on animal cadaver and synthetic foams.en_US
dc.description.sponsorshipThe authors of this study acknowledge to Turkish Science Foundation (TUBITAK) for the financial support for the study with project number of 113S101 and acknowledge to Osimplant Medical Devices for the preparation of the test samples.
dc.language.isoenen_US
dc.publisherSage Publications Ltden_US
dc.relation.ispartofProceedings Of The Institution Of Mechanical Engineers Part H-Journal Of Engineering In Medicineen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPedicle screwen_US
dc.subjectpullout strengthen_US
dc.subjectdual lead dual cored pedicle screwen_US
dc.subjectcannulated screwen_US
dc.subjectcement augmentationen_US
dc.titlePullout performance comparison of pedicle screws based on cement application and design parametersen_US
dc.typeArticleen_US
dc.departmentFaculties, Faculty of Engineering, Department of Mechanical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümütr_TR
dc.identifier.volume229
dc.identifier.issue11
dc.identifier.startpage786
dc.identifier.endpage793
dc.relation.tubitakTurkish Science Foundation (TUBITAK) [113S101]en_US
dc.authorid0000-0001-6352-8302-
dc.identifier.wosWOS:000363967200004en_US
dc.identifier.scopus2-s2.0-84945275605en_US
dc.institutionauthorDemir, Teyfik-
dc.identifier.pmid26503840en_US
dc.identifier.doi10.1177/0954411915612494-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ2-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextnone-
Appears in Collections:Makine Mühendisliği Bölümü / Department of Mechanical Engineering
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

11
checked on Apr 20, 2024

WEB OF SCIENCETM
Citations

13
checked on Apr 13, 2024

Page view(s)

36
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.