Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/2794
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRoy, Rupak Bardhan-
dc.contributor.authorBozkurt, Ayhan-
dc.contributor.authorFarhanieh, Omid-
dc.contributor.authorErgün, Arif Şanlı-
dc.date.accessioned2019-12-25T14:03:39Z-
dc.date.available2019-12-25T14:03:39Z-
dc.date.issued2015-12
dc.identifier.citationRoy, R. B., Bozkurt, A., Farhanieh, O., and Ergun, A. S. (2015, November). Embedded sacrificial layers for CMUT fabrication. In 2015 IEEE SENSORS (pp. 1-4). IEEE.en_US
dc.identifier.isbn978-1-4799-8203-5
dc.identifier.issn1930-0395
dc.identifier.urihttps://hdl.handle.net/20.500.11851/2794-
dc.identifier.urihttps://ieeexplore.ieee.org/document/7370642-
dc.identifier.urihttp://research.sabanciuniv.edu/28133/1/sensors.pdf-
dc.description.abstractCapacitive Micromachined Ultrasonic Transducers (CMUTs) are generally fabricated either by conventional sacrificial release process or by wafer bonding technique. In the former, sacrificial layers are patterned with deposited materials on the substrate. This current work reports a development on the aforementioned technique wherein sacrificial islands are embedded inside grooves opened by DRIE in the substrate itself. The depth of the grooves and the thickness of the sacrificial layer are identical in dimension. As the first membrane layer between the top electrode and vacuum gap reduces the device sensitivity, it needs to be kept as thin as possible. Conformality of the deposition technique, however, requires a deposition thickness at least equal to the sacrificial layer. Hence one cannot go below a certain first membrane layer thickness. The present method is expected to solve such problems in CMUT fabrication. The present technique keeps the substrate completely flat even after sacrificial patterning, hence aiding the consecutive process steps such as electrode deposition and patterning. The described method does not increase process complexity other than an additional RIE step. Using this technique CMUTs with 5.6 MHz center frequency have been manufactured and tested.en_US
dc.description.sponsorshipIEEE Sensors Council, IEEE Societies
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.ispartof2015 IEEE SENSORSen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectUltrasonic transducersen_US
dc.subjecttransducersen_US
dc.subjectcapacitive micromachineden_US
dc.titleEmbedded Sacrificial Layers for CMUT Fabricationen_US
dc.typeConference Objecten_US
dc.departmentFaculties, Faculty of Engineering, Department of Electrical and Electronics Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Elektrik ve Elektronik Mühendisliği Bölümütr_TR
dc.identifier.startpage1791
dc.identifier.endpage1794
dc.authorid0000-0002-6193-5761-
dc.identifier.wosWOS:000380440800470en_US
dc.identifier.scopus2-s2.0-84963502844en_US
dc.institutionauthorErgün, Arif Şanlı-
dc.identifier.doi10.1109/ICSENS.2015.7370642-
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.identifier.scopusquality--
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.openairetypeConference Object-
item.grantfulltextnone-
Appears in Collections:Elektrik ve Elektronik Mühendisliği Bölümü / Department of Electrical & Electronics Engineering
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

5
checked on Apr 20, 2024

Page view(s)

14
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.