Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/3687
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSadık, Demet Ataman-
dc.contributor.authorBoyacı, İsmail Hakkı-
dc.contributor.authorMutlu, Mehmet-
dc.date.accessioned2020-09-17T14:43:37Z-
dc.date.available2020-09-17T14:43:37Z-
dc.date.issued2019-10-30
dc.identifier.citationSadık, D. A., Boyacı, İ. H., & Mutlu, M. (2019). Mixed monolayer decorated SPR sensing surface for thrombin detection. Journal of pharmaceutical and biomedical analysis, 176, 112822.en_US
dc.identifier.issn0731-7085
dc.identifier.otherarticle number 112822, number of pages 9
dc.identifier.urihttps://hdl.handle.net/20.500.11851/3687-
dc.identifier.urihttps://doi.org/10.1016/j.jpba.2019.112822-
dc.description.abstractThe development of surface plasmon resonance (SPR) based immunosensor for thrombin detection was aimed. For this purpose, 3,3? Dithiodipropionic acid di (N-hydroxysuccinimide ester) (DSP):6-mercapto-1-hexanol (MCH) mixed self-assembled monolayers (mSAMs) were formed on gold surfaces for immobilization of anti-thrombin antibody. The performance of the immunosensor was determined against the target protein thrombin at various concentrations using flow cell coupled SPR. The linear detection range of the immunosensor was 30.0–100.0 nM with an R2 value of 0,992. Limit of Detection (LOD) and Limit of Quantification (LOQ) were determined to be 6.0 nM and 30.0 nM, respectively. The selectivity of the immunosensor was tested against a non-target model protein, human serum albumin (HSA) and the obtained ?RU value was found to be below the ?RU value corresponding to the LOQ concentration for thrombin. The immunosensor's capability to detect thrombin in diluted complex serum matrix was also tested and the obtained ?RU value (159 ± 16) was compared with ?RU value obtained for thrombin detection in PBS solution (137 ± 19). Based on the results, it was shown that DSP:MCH interface is a promising immobilization platform for binding biological recognition elements for the development of biosensors.en_US
dc.language.isoenen_US
dc.publisherElsevier B.V.en_US
dc.relation.ispartofJournal of Pharmaceutical and Biomedical Analysisen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBiosensoren_US
dc.subjectGold surfacesen_US
dc.subject3,3 ' Dithiodipropionic acid di (N-hydroxysuccinimide ester)en_US
dc.subjectDSP:6-mercapto-1-hexanol (MCH)en_US
dc.subjectMixed self-assembled monolayers (mSAMs)en_US
dc.subjectBiological recognition element immobilizationen_US
dc.subjectSurface plasmon resonance (SPR)en_US
dc.titleMixed monolayer decorated SPR sensing surface for thrombin detectionen_US
dc.typeArticleen_US
dc.departmentFaculties, Faculty of Engineering, Department of Biomedical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümütr_TR
dc.identifier.volume176
dc.relation.tubitakinfo:eu-repo/grantAgreement/TÜBİTAK/TBAG/211T103en_US
dc.authorid0000-0001-7146-1937-
dc.identifier.wosWOS:000489000700021en_US
dc.identifier.scopus2-s2.0-85071128263en_US
dc.institutionauthorMutlu, Mehmet-
dc.identifier.pmid31454662en_US
dc.identifier.doi10.1016/j.jpba.2019.112822-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.relation.otherHacettepe University, Scientific Research Projects Coordination Unit, Turkey [FHD-2016-8989]
dc.identifier.scopusqualityQ1-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.openairetypeArticle-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
crisitem.author.dept02.2. Department of Biomedical Engineering-
Appears in Collections:Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Apr 27, 2024

WEB OF SCIENCETM
Citations

8
checked on Apr 27, 2024

Page view(s)

112
checked on Apr 29, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.