Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/3694
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYaşar, Abdullah İrfan-
dc.contributor.authorYıldız, Fikret-
dc.contributor.authorEroğul, Osman-
dc.date.accessioned2020-09-17T14:43:39Z-
dc.date.available2020-09-17T14:43:39Z-
dc.date.issued2019-11
dc.identifier.citationYaşar, A. İ., Yildiz, F., & Ero?ul, O. (2019, November). Evaluation of CMUT performance under different excitation signals and electrode coverage. In 2019 11th international conference on electrical and electronics engineering (ELECO) (pp. 441-444). IEEE.en_US
dc.identifier.isbn9786050112757
dc.identifier.otherarticle number 8990518
dc.identifier.urihttps://hdl.handle.net/20.500.11851/3694-
dc.identifier.urihttps://ieeexplore.ieee.org/document/8990518-
dc.description.abstractCMUT output characteristics with different top electrode coverages were investigated by driving different excitation signals. Membrane displacements were obtained using a Simulink model. Membrane displacements were examined for three cases of electrode coverage, one-quarter, half and entire of the membrane area. The diameter and thickness of the CMUT membrane used in the simulation were 60 pm and 2.6 pm. First, the collapse voltages were found by using numerical calculations. Then these values were analyzed using the Simulink model. It was understood that electrode coverage affected the collapse voltage of CMUT. After that, analyzes were made for AC signals of different types (sawtooth, sine, and square) and different amplitudes DC bias voltages and AC excitation signals. Our results showed that CMUT has the highest displacement in the case of 100% electrode coverage when excited in square signal is used.en_US
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.ispartof2019 11th International Conference on Electrical and Electronics Engineering (ELECO)en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleEvaluation of CMUT Performance under Different Excitation Signals and Electrode Coverageen_US
dc.typeConference Objecten_US
dc.departmentFaculties, Faculty of Engineering, Department of Biomedical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümütr_TR
dc.identifier.startpage441
dc.identifier.endpage444
dc.authorid0000-0002-4640-6570-
dc.identifier.wosWOS:000552654100085en_US
dc.identifier.scopus2-s2.0-85080494094en_US
dc.institutionauthorEroğul, Osman-
dc.identifier.doi10.23919/ELECO47770.2019.8990518-
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
item.cerifentitytypePublications-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeConference Object-
item.fulltextNo Fulltext-
item.grantfulltextnone-
crisitem.author.dept02.2. Department of Biomedical Engineering-
Appears in Collections:Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Apr 13, 2024

WEB OF SCIENCETM
Citations

1
checked on Jan 20, 2024

Page view(s)

108
checked on Apr 15, 2024

Google ScholarTM

Check




Altmetric