Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/4020
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYalçın, Asena-
dc.contributor.authorOlgar, Turan-
dc.contributor.authorSancak, Tanzer-
dc.contributor.authorAtaç, Gökçe Kaan-
dc.contributor.authorAkyar, Serdar-
dc.date.accessioned2021-01-22T06:27:46Z-
dc.date.available2021-01-22T06:27:46Z-
dc.date.issued2020-09
dc.identifier.citationYalcin, A., Olgar, T., Sancak, T., Atac, G. K., & Akyar, S. (2020). Correlation between physical measurements and observer evaluations of image quality in digital chest radiography. Medical Physics, 47(9), 3935-3944.en_US
dc.identifier.issn0094-2405
dc.identifier.urihttps://hdl.handle.net/20.500.11851/4020-
dc.identifier.urihttps://doi.org/10.1002/mp.14244-
dc.description.abstractPurpose: The aim of this paper was to investigate the relationship between the physical and subjective (observer) image quality metrics in digital chest radiography. Methods: Five digital radiography systems, four with indirect flat panel detector and one with storage phosphor-based computed radiography system, were used in the study. The physical image quality assessments were carried out using effective detective quantum efficiency (eDQE) metric and subjective performance of the digital radiography systems was evaluated in terms of inverse image quality figure (IQFinv) derived from the contrast-detail (CD) diagrams using CDRAD 2.0 phantom and CDRAD phantom analyzer software. All measurements were performed for different tube voltages (70, 81, 90, 102, 110, and 125 kVp) and polymethyl methacrylate (PMMA) phantom thicknesses. An anthropomorphic chest phantom and visual grading analysis (VGA) technique based on European image quality criteria for chest radiography were used for clinical image quality evaluation. Results: The Spearman correlation coefficients were calculated for the investigation of the correlation between physical image quality and clinical image quality. The results showed strong positive correlation between the physical and clinical image quality findings. The minimum correlation coefficient was 0.91 (p < 0.011) for IQFinv vs VGA scores and 0.92 (p < 0.009) for IeDQE vs VGA scores. Conclusions: Our results confirm that clinical image quality can be predicted with both physical assessments and contrast-detail detectability studies.en_US
dc.language.isoenen_US
dc.publisherJohn Wiley and Sons Ltden_US
dc.relation.ispartofMedical Physicsen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectintegrated effective detective quantum efficiency (IeDQE)en_US
dc.subjectimage quality figure (IQF)en_US
dc.subjectvisual grading analysis (VGA)en_US
dc.titleCorrelation between physical measurements and observer evaluations of image quality in digital chest radiographyen_US
dc.typeArticleen_US
dc.departmentFaculties, School of Medicine, Department of Internal Medical Sciencesen_US
dc.departmentFakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümütr_TR
dc.identifier.volume47
dc.identifier.issue9
dc.identifier.startpage3935
dc.identifier.endpage3944
dc.authorid0000-0003-1968-7714-
dc.identifier.wosWOS:000548679100001en_US
dc.identifier.scopus2-s2.0-85087969706en_US
dc.institutionauthorSancak, İbrahim Tanzer-
dc.identifier.pmid32427360en_US
dc.identifier.doi10.1002/mp.14244-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ1-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.fulltextNo Fulltext-
item.grantfulltextnone-
Appears in Collections:Dahili Tıp Bilimleri Bölümü / Department of Internal Medical Sciences
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Apr 13, 2024

WEB OF SCIENCETM
Citations

8
checked on Apr 13, 2024

Page view(s)

42
checked on Apr 15, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.