Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/4166
Title: Effects of Cyclotorsion Orientation and Magnitude in Eyes with Compound Myopic Astigmatism on the Compensation Capacity of WaveLight EX500 Photorefractive Keratectomy
Authors: Özülken, Kemal
Çağrı, İlhan
Keywords: Astigmatism
Lasers
Myopia
Photorefractive keratectomy
Refractive surgical procedures
Publisher: Korean Ophthalmological Society
Source: Ozulken, K., & Ilhan, C. (2019). Effects of Cyclotorsion Orientation and Magnitude in Eyes with Compound Myopic Astigmatism on the Compensation Capacity of WaveLight EX500 Photorefractive Keratectomy. Korean journal of ophthalmology: KJO, 33(5), 458.
Abstract: Purpose To investigate the clinical effects of different orientation and magnitude of cyclotorsion on the compensation capacity of the WaveLight EX500 photorefractive keratectomy (PRK) platform. Methods This retrospective study comprised 400 eyes of 200 patients who underwent bilateral simultaneous PRK due to compound myopic astigmatism. The subjects were separated according to the orientation of cyclotorsion into incyclotorsion and excyclotorsion groups, and by the magnitude of cyclotorsion into group 1 (0.50 to 2.50 degrees), group 2 (3.00 to 5.00 degrees), group 3 (5.50 to 7.50 degrees), and group 4 (8.00 to 9.50 degrees). Results The mean magnitude of cyclotorsion was 3.50 ± 2.4 degrees (0.50 to 9.50 degrees) in the incyclotorsion group and 3.32 ± 2.3 degrees (0.50 to 9.50 degrees) in the excyclotorsion group (p = 0.617). The postoperative refractive outcomes of the incyclotorsion and excyclotorsion groups were similar (p > 0.05 for all). The postoperative mean cylindrical refractive error was −0.32 ± 0.3 diopters (D, −1.25 to 0.00 D) in group 1, −0.47 ± 0.2 D (−2.00 to 0.00 D) in group 2, −0.62 ± 0.2 D (−1.00 to −0.25 D) in group 3, and −0.91 ± 0.2 D (−1.50 to −0.50 D) in group 4 (p < 0.001). Preoperative cylindrical refractive error was positively correlated with magnitude of cyclotorsion (r = 0.125 and p = 0.013), which was also positively correlated with postoperative cylindrical refractive error (r = 0.600 and p < 0.001). Conclusions Incyclotorsion and excyclotorsion can be equally compensable in the WaveLight EX500 PRK platform for compound myopic astigmatism. A value of ≤2.50 degrees cyclotorsion magnitude was observed to be more compensable than higher degrees of cyclotorsion magnitude. Preoperative high astigmatism was associated with high cyclotorsion magnitude, which was also associated with a high degree of postoperative astigmatism.
URI: https://hdl.handle.net/20.500.11851/4166
https://doi.org/10.3341/kjo.2019.0042
ISSN: 1011-8942
Appears in Collections:Cerrahi Tıp Bilimleri Bölümü / Department of Surgical Sciences
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
EffectsofCyclotorsion.pdf466.09 kBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

Page view(s)

84
checked on Apr 22, 2024

Download(s)

18
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.