Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/7869
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorErgün, Arif Sanlı-
dc.contributor.authorAykul, Serkan-
dc.date.accessioned2021-12-02T17:20:17Z-
dc.date.available2021-12-02T17:20:17Z-
dc.date.issued2013-
dc.identifier.citationAykul, Serkan. (2013). Yüksek genlikli odaklı ultrason transdüser dizinine verilecek fazların MR görüntüleri yardımı ile oluşturulması. (Yayınlanmamış Yüksek Lisans Tezi). TOBB Ekonomi ve Teknoloji Üniversitesi, Fen Bilimleri Enstitüsü, Elektrik-Elektronik Mühendisliği Ana Bilim Dalıen_US
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=iTkOhwevEenJZ3onUvs52vphNZoa94VduKbPSvygyqzh89xDvW29H6nuFY7aS-9Z-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/7869-
dc.descriptionYÖK Tez No: 346537en_US
dc.description.abstractGünümüzde, yüksek genlikli odaklı ultrason (HIFU) doku ısıtma, doku yakma, kan pıhtılaştırma ve taş kırma gibi pek çok uygulamada kullanılmakta ve önemi her geçen gün artmaktadır. HIFU uygulamalarında karşılaşılan önemli problemlerden biri faz hataları nedeni ile odak noktasının kayması ve dağılmasıdır. Homojen ortamlarda herhangi bir noktaya doğru bir şekilde odaklamak için ultrasonik transdüser elemanlarına uygulanacak fazlar kesin olarak hesaplanabilir. Fakat insan vücudu gibi homojen olmayan ortamlarda dokular arası ses hızı farklılıkları faz hatalarına sebep olur. Transdüser dizini ile hedef nokta arasında bulunan dokunun her bir noktasındaki ses hızlarını bilmemiz durumunda bu faz hatalarının oluşması engellenebilir. Manyetik Rezonans (MR) görüntüleri bize dokudaki ses hızı ile ilgili bilgileri sağlayabilir ve bu sayede MR güdümlü Isıl tedavi (MRgFUS) sürecinde bu faz hatalarının olması engellenerek bu süreç hızlandırılabilinir. Bu çalışmada MR görüntülerinden dokudaki su ve yağ ağırlıkları belirlenerek dokunun ses hızının bulunmasına çalışılmış ve bulunan ses hızları ile yaratılan ortamlarda ters yayılım methodu ve sesin kırılmadığı varsayımı ile çeşitli denemeler yapılarak istenilen hedef noktası için transdüser dizinine verilmesi gereken fazlar başarı ile hesaplanmıştır.en_US
dc.description.abstractHigh Intensity Focused Ultrasound (HIFU) is becoming increasingly available for ablation of unwanted tissue, for coagulation of blood and for crushing kidney stones. One of the important problems associated with HIFU is the smearing and spatial shift of the focal spot due to phase errors. For a homogeneous medium the phase delays associated with each ultrasonic array element to form a beam is known exactly. However, when the medium is inhomogeneous like human body, the variations in the speed of sound cause phase errors. Knowing the speed of sound in tissue between the transducer array and target greatly remedies this problem. The information obtained from MR images can be used to correct the phase of each transducer element. In this way, treatment duration for MRgFUS reduces. In this study we used water supressed and fat supressed MR images for determining the speed of sound in tissue then we used this information and some methods, like backprojection, to compute the phase delays associated with each aray element of the HIFU transducer.en_US
dc.language.isotren_US
dc.publisherTOBB Ekonomi ve Teknoloji Üniversitesien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectElektrik ve Elektronik Mühendisliğien_US
dc.subjectElectrical and Electronics Engineeringen_US
dc.titleYüksek genlikli odaklı ultrason transdüser dizinine verilecek fazların MR görüntüleri yardımı ile oluşturulmasıen_US
dc.title.alternativeComputing the beamforming phase delays applied to individual elements of high intensity focused ultasound transducer array based on MR imagesen_US
dc.typeMaster Thesisen_US
dc.departmentFaculties, Faculty of Engineering, Department of Electrical and Electronics Engineeringen_US
dc.departmentEnstitüler, Fen Bilimleri Enstitüsü, Elektrik ve Elektronik Mühendisliği Ana Bilim Dalıtr_TR
dc.identifier.startpage1en_US
dc.identifier.endpage50en_US
dc.institutionauthorAykul, Serkan-
dc.relation.publicationcategoryTezen_US
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1tr-
item.cerifentitytypePublications-
item.openairetypeMaster Thesis-
item.grantfulltextopen-
Appears in Collections:Elektrik-Elektronik Mühendisliği Yüksek Lisans Tezleri / Electrical & Electronics Engineering Master Theses
Files in This Item:
File SizeFormat 
346537.pdf1.34 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

50
checked on Apr 22, 2024

Download(s)

4
checked on Apr 22, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.