Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/8299
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOdabaşı, Ersin-
dc.contributor.authorTuran, Mustafa-
dc.date.accessioned2022-01-15T13:02:27Z-
dc.date.available2022-01-15T13:02:27Z-
dc.date.issued2022-
dc.identifier.issn0020-7128-
dc.identifier.issn1432-1254-
dc.identifier.urihttps://doi.org/10.1007/s00484-021-02201-1-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/8299-
dc.description.abstractIt is not wrong to say that there are no application standards or best practices in balneotherapy considering traditional applications. There is not enough information about how changes in body temperature, duration, and frequency of exposure to heat affect therapeutic outcomes of balneotherapeutic applications. Body core temperature (BCT) is probably the best parameter for expressing the heat load of the body and can be used to describe the causal relationship between heat exposure and its effects. There are several reasons to take BCT changes into account; for example, it can be used for individualized treatment planning, defining the consequences of thermal effects, developing disease-specific approaches, avoiding adverse effects, and designing clinical trials. The reasons why BCT changes should be considered instead of conventional measures will be discussed while explaining the effects of balneotherapy in this article, along with a discussion of BCT measurement in balneotherapy practice.en_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofInternational Journal of Biometeorologyen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBalneotherapyen_US
dc.subjectBody core temperatureen_US
dc.subjectHeaten_US
dc.subjectHydrotherapyen_US
dc.subjectMedical mud treatmenten_US
dc.subjectSkin Blood-Flowen_US
dc.subjectMultiple-Sclerosisen_US
dc.subjectSpa Therapyen_US
dc.subjectHot-Tuben_US
dc.subjectKnee Osteoarthritisen_US
dc.subjectOral-Temperatureen_US
dc.subjectHeaten_US
dc.subjectThermometersen_US
dc.subjectIndividualsen_US
dc.subjectAccuracyen_US
dc.titleThe importance of body core temperature evaluation in balneotherapyen_US
dc.typeReviewen_US
dc.departmentFaculties, School of Medicine, Department of Basic Medical Sciencesen_US
dc.departmentFakülteler, Tıp Fakültesi, Temel Tıp Bilimleri Bölümütr_TR
dc.identifier.volume66en_US
dc.identifier.issue1en_US
dc.identifier.startpage25en_US
dc.identifier.endpage33en_US
dc.identifier.wosWOS:000705712800001en_US
dc.identifier.scopus2-s2.0-85116790332en_US
dc.institutionauthorTuran, Mustafa-
dc.identifier.pmid34623501en_US
dc.identifier.doi10.1007/s00484-021-02201-1-
dc.authorscopusid6506133156-
dc.authorscopusid7005400759-
dc.relation.publicationcategoryDiğeren_US
dc.identifier.scopusqualityQ2-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.openairetypeReview-
item.grantfulltextnone-
crisitem.author.dept03.14. Department of Internal Medicine-
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Temel Tıp Bilimleri Bölümü / Department of Basic Medical Sciences
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

WEB OF SCIENCETM
Citations

2
checked on Apr 20, 2024

Page view(s)

70
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.