Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/5393
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÇelebioğlu, Kutay-
dc.date.accessioned2021-09-11T14:39:20Z-
dc.date.available2021-09-11T14:39:20Z-
dc.date.issued2019en_US
dc.identifier.issn1300-3453-
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/403572-
dc.identifier.urihttps://doi.org10.18400/tekderg.447265-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/5393-
dc.description.abstractWhen highly calcinated water is transferred through the penstock of a hydropower plant it leaves a residue on the pipe surface. Accumulated residue over time causes a change in the roughness of the pipe surface thus leads to friction losses in the system. The effect is a change in head and discharge relation for the turbines. A multimethodology is proposed for determining the apparent surface roughness value (?) by means of friction factor f and measuring arithmetic mean deviation of the roughness profile (Ra), root mean square roughness (Rq) and peak and valley roughness (Rz). It is found that a surface roughness value (?) of 0.3mm can be used for calcinated surfaces which is much higher than steel surfaces but smaller than a concrete surface.en_US
dc.language.isoenen_US
dc.relation.ispartofTeknik Dergien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleRoughness Coefficient of a Highly Calcinated Penstocken_US
dc.typeArticleen_US
dc.departmentFaculties, Faculty of Engineering, Department of Mechanical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümütr_TR
dc.identifier.volume30en_US
dc.identifier.issue4en_US
dc.identifier.startpage9309en_US
dc.identifier.endpage9325en_US
dc.identifier.wosWOS:000473531600005en_US
dc.identifier.scopus2-s2.0-85086443123en_US
dc.institutionauthorÇelebioğlu, Kutay-
dc.identifier.doi10.18400/tekderg.447265-
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ4-
dc.identifier.trdizinid403572en_US
item.cerifentitytypePublications-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.fulltextNo Fulltext-
item.grantfulltextnone-
crisitem.author.dept13. TOBB ETÜ HIDRO Water Turbine Design and Test Center-
Appears in Collections:Rektörlük / Rectorate
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
TR Dizin İndeksli Yayınlar / TR Dizin Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

1
checked on Apr 20, 2024

WEB OF SCIENCETM
Citations

1
checked on Apr 6, 2024

Page view(s)

168
checked on Apr 15, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.