Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/889
Title: Comparison of rigid and semi-rigid instrumentation under acute load on vertebrae treated with posterior lumbar interbody fusion/transforaminal lumbar interbody fusion procedures: An experimental study
Authors: Önen, Mehmet Reşid
Başgül, Cemile
Yılmaz, İlhan
Özkaya, Mustafa
Demir, Teyfik
Naderi, Sait
Keywords: rigid fixation
Semi-rigid fixation
compression load
fracture energy
drop mechanism
posterior fusion
load sharing
polyetheretherketone rod
transforaminal lumbar interbody fusion
posterior lumbar interbody fusion
Publisher: SAGE Publications Ltd
Source: Önen, M. R., Başgül, C., Yılmaz, İ., Özkaya, M., Demir, T., & Naderi, S. (2018). Comparison of rigid and semi-rigid instrumentation under acute load on vertebrae treated with posterior lumbar interbody fusion/transforaminal lumbar interbody fusion procedures: An experimental study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 232(4), 388-394.
Abstract: Rigid and semi-rigid fixations are investigated several times in order to compare their biomechanical stability. Interbody fusion techniques are also preferable for maintaining the sagittal balance by protecting the disk height. In this study, the biomechanical comparison of semi-rigid and rigid fixations with posterior lumbar interbody fusion or transforaminal lumbar interbody fusion procedures is conducted under trauma. There were four different test groups to analyze the effect of acute load on treated ovine vertebrae. First and second groups were fixed with polyetheretherketone rods and transforaminal lumbar interbody fusion and posterior lumbar interbody fusion cages, respectively. Third and fourth groups were fixed with titanium rods and posterior lumbar interbody fusion and transforaminal lumbar interbody fusion cages, respectively. The drop tests were conducted with 7 kg weight. There were six samples in each group so the drop test repeated 24 times in total. The test samples were photographed and X-rayed (laterally and anteroposteriorly) before and after drop test. Two fractures were observed on group 1. Conversely, there were no fractures observed for group 2. There were no anterior element fractures for both groups 1 and 2. However, one fracture seen on group 3 was anterior element fracture, whereas the other three were posterior element fractures. All three fractures were anterior element fractures for group 4. Treated vertebrae with polyetheretherketone rods and posterior lumbar interbody fusion cages showed the best durability to the drop tests among the groups. Semi-rigid fixation gave better results than rigid fixation according to failed segments. Posterior lumbar interbody fusion cages seem to be better option for semi-rigid fixation, however mentioned surgical disadvantages must be considered.
URI: https://doi.org/10.1177/0954411918755416
https://hdl.handle.net/20.500.11851/889
ISSN: 0954-4119
Appears in Collections:Makine Mühendisliği Bölümü / Department of Mechanical Engineering
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Apr 20, 2024

WEB OF SCIENCETM
Citations

3
checked on Apr 20, 2024

Page view(s)

52
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.